Design and Construction of 0 500V 3KVA Variac with Digital Display - International Journal of Trend in Scientific Research and Development

IJTSRD is a leading Open Access, Peer-Reviewed International Journal which provides rapid publication of your research articles and aims to promote the theory and practice along with knowledge sharing between researchers, developers, engineers, students, and practitioners working in and around the world in many areas. For any further information, feel free to write us on editor.ijtsrd@gmail.com

Friday, 4 October 2019

Design and Construction of 0 500V 3KVA Variac with Digital Display

The design and construction of 3KVA variac ranging from 0 500V with a digital display was carried out due to the fact that every electrical, electronic and laboratory appliances equipments are designed and manufactured to operate based on the expectation that the input voltage would be at certain value. In Nigeria, household electrical electronic appliances and also laboratory equipments are most time under threat of low voltage supply. Since the electric power supply distribution companies are unable to provide the consistent and adequate voltage level 220V demanded by these sensitive appliances. The design and construction of a 3000VA variac variable transformer with an input voltage of 230V to give an output of 0 500V is aimed at providing solutions to this driving issue of low voltage and also to update in the growing trend of digitalization using a digital display. The method applied to achieve this project include faradays law of induction, ohms law, e.m.f equation of transformer and voltage transformer ratio k ,where the number of turns in for the primary is 136turns and the secondary is 297turns approx. . The major components used to achieve this work are the copper wires and the laminated steels core also known as the toroidal core. The designed and constructed variac was tested with an input of 230V and the output result of 500Vmaximum was confirmed ok. If designed and properly constructed with standard electrical components and materials it could be used in sub stations as step up for distributions of electricity. It should be designed with heavy gauge coils, higher rated toroidal core and attached an indicator to indicate with beep sound when it is being overloaded above its capacity. 

by Makinde Kayode | Man Alhaji Sulaiman | Lawal Olawale Kazeem "Design and Construction of 0-500V 3KVA Variac with Digital Display"

Published in International Journal of Trend in Scientific Research and Development (ijtsrd), ISSN: 2456-6470, Volume-3 | Issue-6 , October 2019,

URL: https://www.ijtsrd.com/papers/ijtsrd29153.pdf

Paper URL: https://www.ijtsrd.com/engineering/electrical-engineering/29153/design-and-construction-of-0-500v-3kva-variac-with-digital-display/makinde-kayode

review papers, call for paper social science, submit paper online

No comments:

Post a Comment

Ad